PIPENET - CAESAR II - Help

CAESAR II Users Guide (2019 Service Pack 1)

Language
English
Product
CAESAR II
Search by Category
Help
CAESAR II Version
11.0 (2019)

Main window Interfaces tab: Hydraulic > PIPENET

Opens the PIPENET Transfer - Generate DLF File dialog box, imports a PIPENET .frc ASCII text file, creates CAESAR II dynamic input data files (.dlf) containing response spectra, and creates a CAESAR II dynamic input file (._7).

Filename

Component List

Hydraulic Name

CAESAR II Node Name

Max. points on each DLF curve

Frequency Cut-off (Hertz)

Open in Dynamic Analysis

Response spectra input files contain dynamic pipe forces. These time history loads are determined from pressure transient loading by the Sunrise System's PIPENET package. The PIPENET interface reads the output file generated by PIPENET, extracts the information needed, and generates the response spectra. The generated response spectrum files can then be used for the dynamic analysis in CAESAR II.

For information on editing ASCII text, see ASCII Text File Rules.