Nozzle Flex - CAESAR II - Help

CAESAR II Users Guide (2019 Service Pack 1)

Language
English
Product
CAESAR II
Search by Category
Help
CAESAR II Version
11.0 (2019)

Indicates that you are supplying nozzle data. Select or clear this option by double-clicking Nozzle Flex on the Classic Piping Input dialog box.

The Nozzles tab in the Piping Input auxiliary panel controls options for flexible nozzle connections. When you type values in this dialog box tab, CAESAR II automatically calculates the flexibilities and adds them to the active element. CAESAR II calculates nozzle loads according to your specified criteria. You can select WRC 297, API 650, PD 5500, or Custom in the Nozzle Type box.