The Hanger Table report provides basic information regarding spring hangers either selected by CAESAR II or by you:
-
Node number
-
Number of springs required
-
Hanger table figure number and size
-
Hot load
-
Theoretical installed load (the hanger setting in the field prior to pulling the pins)
-
Actual installed load (the load on the hanger when the pipe is empty)
-
Spring rate from the catalog
-
Horizontal movement determined from the CAESAR II output.
-
Hanger constant effort force (provided when constant effort supports are selected)
The Hanger Table with Text report displays more descriptive text and includes additional information:
-
Variable support spring designed
-
Maximum and minimum allowed single spring load
-
Recommended installation clearance as read from the catalogs