Define up to 999 load cases.
Add recommended load cases
-
From the Classic Piping Input Tab, select Edit Static Load Cases
to display the Static Analysis - Load Case Editor Dialog. Loads based on the parameters specified in Piping Input display in the left pane.
-
Select Recommend Load Cases
to display the Basic and Combination Load Cases and stress types that satisfy the model parameters and the basic requirements of the selected piping code.
-
To delete, select the load case row, and then select Delete a load case
.
-
To modify, change the values of any field, including the Definition.
Add a new basic load case
-
Select a row and select Add a load case
. The software adds a new row after the selected row.
-
Select one or more loads in the Loads Defined in Input pane and drag the loads to the Definition field. The software adds the loads.
-OR-
Type the load names with an operator (usually +) between them in the Definition field.
-
Type a Name and select a Stress Type.
-
Define other fields as needed.
-
Select Save.
Add a new combination load case
Combination load cases must follow the basic load cases.
-
Select the last row and select Add a load case
. The software adds a new row after the last row.
-
Select one or more Load Cases and drag the load cases to the Definition field. Select the Combination Method.
-
If needed, select one or more loads in the Loads Defined in Input pane and drag the loads to the Definition field
-
Type a Name and select a Stress Type.
-
Define other fields as needed.
-
Select Save.