Computational Control - CAESAR II - Installation & Upgrade

CAESAR II Quick Reference

Language
English
Product
CAESAR II
Search by Category
Installation & Upgrade
CAESAR II Version
14

Convergence Tolerances

Value

Decomposition Singularity Tolerance

1.00e+10

Friction Angle Variation

15.000

Friction Normal Force Variation

0.150

Friction Slide Multiplier

1.000

Friction Stiffness

1.00e+6

Rod Increment

2.000

Rod Tolerance

1.000

Input Spreadsheet Defaults

Values

Alpha Tolerance

0.050

Coefficient of Friction

0.000

Default Rotational Restraint Stiffness

1.00e+12

Default Translational Restraint Stiffness

1.00e+12

Hanger Default Restraint Stiffness

1.00e+12

Minimum Wall Tolerance (%)

12.500

New Job Ambient Temperature

70

New Job Bourdon Pressure

None

Miscellaneous

Value

Bend Axial Shape

True

Ignore Spring Hanger Stiffness

False

Include Insulation in Hydrotest

False

Include Spring Hanger Stiffness in Hanger OPE Travel Cases

False

Incore Numerical Check

False

Missing Mass ZPA

Extracted

Use Pressure Stiffening on Bends

Default

WRC-107 Interpolation Method

Last Value

WRC-107 Version

Mar '79 1B1/2B1