The following fixes have been made to CAESAR II:
CAESAR II Version 13.00
Piping Input
-
Corrected the value of Fa used for ASCE 7-16/IBC 2018 in ASCE Static Seismic Wizard calculations. (TR-TX-40644)
Static and Dynamic Analysis
-
Applied an EN-13480 2017 requirement to Pad Thk tp to limit the reinforcing pad thickness to the nominal thickness of the header. (CR-TX-40463)
-
Fixed an issue with a variable angle change for a structural element axis orientation. The issue was caused by a double conversion of the angle from degrees to radians for every elastic modulus selection in the Static Analysis - Load Case Editor Dialog. (TR-TX-39566)
-
Corrected the text for an Error Check warning when Nozzle Flexibility is specified, and the nozzle diameter is greater than one third of the vessel diameter. The text incorrectly stated vessel radius. (TR-TX-27686)
Documentation/Help
-
Corrected an error and clarified usage of the 0.7 multiplier in the ASCE Example for the Seismic Wizard. (TR-TX-36038)
-
Corrected errors in the CFE Sismo Example for the Seismic Wizard. (TR-TX-36040)
-
Corrected equation errors for Widely-Spaced Mitered Bend in the CAESAR II Application Guide.
-
Corrected an equation error for dP - YIELD DISP FACTOR, LAT, MAX MULTIPLE OF D. (TR-TX-39782)
-
Removed an incorrect statement about inclusion of hanger manufacturer information in Available Space (neg. for can). (TR-TX-38403)