Bend Flexibility Factor - CAESAR II - Reference Data

CAESAR II Applications Guide

PPMProduct
CAESAR II
PPMCategory_custom
Reference Data
Version_CAESAR
12

Usually, bend flexibility factors are calculated according to code requirements. However, you can override the code calculation by typing a value for the K-factor. For example, if you type 1.500, then the bend is 1.5 times as flexible as a straight pipe of the same length.