CADWorx Structure tab: Tools panel > Join
Command line: SJOIN
Joins two or more structural members into one member. The following properties must be the same for each member:
-
Member size (W10x30 for example)
-
Insertion location
-
Centerline location
-
Rotation angle
-
Data file
-
Short annotation
-
Long annotation
-
Description
-
Material
-
Part number
In addition, the two center lines must meet, but must not intersect or overlap.
You cannot join curved members and straight members.
-
Click Join on the Tools panel.
You can also type SJOIN in the command line.
-
Select the first member to join.
-
Select the second member to join.
You can also highlight all members to join, and then press ENTER to finish.
-
Continue to select members, or press ENTER to finish.
The software joins the members.