Mouse Icon CADWorx Spec Editor Home tab: Add Table > New End Type New End Type - Custom End Types

Adds a new custom end type to the End Type Tables folder in Catalog Data.

Name

Specifies the name of the custom end type. After you create the custom end type, this name displays in the Type list in the New End Type Table dialog box.

Base End Type

Specifies the base end type for the custom end type. The base end type is one of the default end types delivered with CADWorx Plant.

Isogen Symbol

Specifies the Isogen symbol type for the custom end type. This symbol displays in an isometric drawing after you run ISOGENOUT.

Options

  • Force Match End Type Setup

Forces the custom end type to only allow connections that you defined in the Matching End Type Table. For more information, see Matching End Type Table Dialog Box.

  • Stub-End/Adapter Lap End Type

Specifies the end type as a stub end or adapter lap end type, and enables the Backing Flange option in the New and Edit Component Pane. You can use the Backing Flange option with any component that has a stub end or adapter lap end type. The Stub-End/Adapter Lap End Type is available when you select Flanged as the Base End Type.

  • Disable Weld Insertion

Disables the automatic weld insertion. The software does not place a weld on the component pair containing the custom end type.

  • Disable Gasket Insertion

Disables the automatic gasket insertion. The software does not place a gasket on the component pair containing the custom end type.

  • Disable Bolt Insertion

Disables the automatic bolt insertion. The software does not place a bolt on the component pair containing the custom end type.

  • Force End Type Length within Component Length

Forces the end type length to be included in the overall length of the component. For example, if you have a pipe that is six feet in length, and you have a one inch end type on each end of the pipe, the pipe length is six feet and two inches. If you do not select this option, the pipe length is six feet.

Description

Specifies a description for the new custom end type.