2020 R1 (4.1)

Default value: 10.0
Allowed values: Positive real

Specifies the minimum percentage slope (rise/run) for automatic dimensioning of the vertical leg of sloped pipe when using Automatic . If the pipe slope is under the specified value, then the vertical leg dimension and the associated hatched graphics for the rise are not placed. The horizontal dimension is still placed.

For more information, see Automatic.