CADWorx Plant I tab: Isogen > Isogen Supplemental
Plant menu: Accessory > Isogen > Isogen Supplemental
Command line: ISOGENSUPL
Places supplemental Isogen blocks in the drawing. There are several types of block available for export to Isogen:
-
Isogen_Arrow
-
Isogen_Wall
-
Isogen_Floor
-
Isogen_Instrument
-
Isogen_Break In
-
Insulation
-
Location Point
Arrow, wall, and floor blocks must be inserted along the center line of a pipe component.
Instrument blocks must have the instrument line connected to the end of an olet component, TAP component, or a weld gap component.
Break in (Tie in) points must be connected to the end point of a component.
You must insert LOCATION-POINT on a component. Otherwise, Isogen does not place it in the isometric drawing. You can insert LOCATION-POINT at any location.
Supplemental blocks do not have line numbers. Isogen processes all supplemental blocks in a drawing at the same time.
To add other blocks to this menu, see Adding preview graphics in Graphics / Pipe Ends. The block name must contain Isogen_Arrow, Isogen_Instrument, Isogen_Wall, Isogen_Floor, or Isogen_BreakIn for export to Isogen. For example, to add another instrument type, you could name the block Isogen_Instrument_4, and add it to the menu.
If you are placing a flow arrow on a sloped line, align the UCS to the slope before inserting the arrow.