Compares data in the Plant and P&ID tables in the project database and shows the components that are not linked.
P&ID Project CFG
Browse to the CFG file for the P&ID project.
Refresh
Reload the list of components for the P&ID and Plant Data fields.
Column Options
Select the columns to display in the P&ID and Plant Data windows.
Filter
You can use the filters to isolate components in the P&ID and Plant Data.
-
Component Type
-
Size
-
Spec
-
Long Description
-
Short Description
-
Line Number
-
Show
-
Limit the line numbers shown in the Line Number field to only show those in the Plant Database or the P&ID Database.
-
P&ID Data window
Displays line numbers and components from the P&ID database that are not linked to corresponding objects in the Plant database. Columns can be added to show more information by changing the settings in Column Options.
-
Route - Route the P&ID object in the drawing.
-
Insert - Insert the P&ID object into the drawing.
Plant Data window
Displays line numbers and components from the Plant database that are not linked to corresponding objects in the P&ID database.
Linked Items
Displays the percentage of components that are linked for CADWorx P&ID and CADWorx Plant.
Link
Highlight an item in each window and then click Link to pair the components in the database.
Valves, reducers, and nozzles can be linked. Instrument components cannot be linked.
Linking Components
-
Click the check box next to an item in the P&ID Data list and an item in the Plant Data list.
-
Click Link.