Mouse Icon CADWorx Plant I tab: Bolt > Standard

Mouse Icon Gaskets, Etc. toolbar: Standard

Keyboard Command line: PLACEBOLT

Inserts stud bolt sets into the drawing environment for Bill of Materials extraction. You can insert a stud bolt set anywhere in the drawing. However, stud bolt sets must be attached to a flange set or flange valve set to be placed on the model. Size and specification must be set accordingly.

If the bolt Weight equals 0.0 in the Stud Bolts data table, the software calculates the weight using the Density value from the Material Table and the CAD platform solid volume of the whole set of bolts.

If the bolt Weight is greater than 0.0, then the following applies:

  • The software calculates the bolt weight as long as the bolt length calculated in the model is longer than in the data table.

Bolt weight = (Actual bolt length / length value of the data table)*Weight value of the data table.

This option is set when the bolt piping rule is set. For more information, see Piping Rules and Apply Bolt Insertion Rule. If you need to change the bolt set by the bolt piping rule, delete the bolt placed and place a bolt using this option.