Specifies a polyline block representation required for different process lines.
Line Break Priority
Specifies the polyline width according to the startup variable values defined in the Configuration File Dialog Box. Select Major primary, Major secondary, Minor primary, or Minor secondary. The selected value also places values in Line thickness and Description.
Database Options
Specifies a database to the polyline. Select Process Line with database, Instrument Line with database, or Instrument Line without database.
Line thickness
Select Major primary, Major secondary, Minor primary, or Minor secondary to use the line thickness assigned to these settings in the Configuration File Dialog Box. You can also type a decimal value for this setting.
LineType
Specifies a line type. The line types are provided by the [Product Folder]\P&ID\Support\Cfm.lin file and any Acad.lin file located within the AutoCAD search path, or any Default.lin file located within the BricsCAD search path.
Layer name
Specifies the drawing layer on which the block is placed.
Line Function
Specifies the text that displays in the Line Function field of the Menu Maintenance dialog box and the Editing Line Component Dialog Box.
Optional
Spec type
Defines a component specification for the block. Click Select to select the specification. The software reads information from the selected specification and populates the appropriate columns in the database. These columns must be pre-named as described in Column Setup (Database Table Setup Dialog Box) of Table Setup . P&ID and CADWorx Plant can use the same pipe specifications. They can also be placed in a common area as defined by SpecificationDirectory in the Configuration File dialog box.
The menu symbol file, Flow_alt.dat, contains the function pline_run. The Poly Line tab controls this function.