The file name requested for this component is not as listed in the specification.

Please verify that the file is still located in the folder as pointed to by the specification. This can be accomplished by editing the currently set specification and locating the component that was used. The file library and the file name are listed at the top of the edit box. This will help in determining what is missing. For further help, see Appendix A of the CADWorx Plant User's Guide.

O-let components read the pipe entry within the specification to determine the pipe wall thickness. Make sure the current specification file has an entry for a pipe component with main and reduction size of the O-let component currently being drawn. For example, a 10" x 2" O-let will require a 10" and a 2" pipe entry in the specification file.

Lap joint flanges read the stub end entry within the specification to determine the lap joint thickness. Make sure the current specification file has an entry for a stub end component with size of the lap joint component currently being drawing.