  1. Expand Flanges. If you are not in the 150 specification, double-click to open it, and then expand Flanges.

  2. Click FLG WELD NECK, 150LB, SCH XS, ASTM A105.

  3. In the Edit component pane, select GAS_150 from the Applicable Gaskets list and BLT_150 from the Applicable Bolts list.

  4. Click Apply.

  5. Click FLG WELD NECK, 150LB, SCH XS, ASTM A105 Part A

  6. In the Edit component pane, reselect FLG_WN_150 from the Data Table list.

    The Applicable Gaskets and Applicable Bolts boxes populate.

  7. In the Edit component pane, add GAS_150A from the Applicable Gaskets list and BLT_150A from the Applicable Bolts list.

  8. Click Apply.

  9. Click FLG WELD NECK, 150LB, SCH XS, ASTM A105 Part B.

  10. In the Edit component pane, select GAS_150 and GAS_150B in the Applicable Gaskets list.

  11. Select BLT_150A and BLT_150B in the Applicable Bolts list.

  12. Click Apply.

  13. Click FLG WELD NECK, 150LB, SCH XS, ASTM A105 Part C.

  14. In the Edit component pane, type GAS_150, GAS_150A, and GAS_150B in the Applicable Gaskets list.

  15. Then, type BLT_150, BLT_150A, and BLT_150B in the Applicable Bolts list.

    The Applicable Gaskets and Applicable Bolts boxes populate.

  16. Click Apply.

  17. Click File > Save.

Next, Assign gaskets and bolts to valves in the project.