The ManualDamper sheet in the HVAC.xls workbook defines the manual dampers available in the Catalog.
PartNumber
Type the part number assigned to the manual damper. The software uses the part number at placement when the part name is automatically generated. An example is PDS-100.
SymbolDefinition
Type the definition of the symbol that you are creating for the manual damper.
FaceWidth
Type the width of the face for the damper.
FaceDepth
Type the face depth for the damper.
ComponentType
Type the component type for the damper.
PartDescription
Type a description for the damper. An example is Manual Damper Part.
DryWeight
Type a dry weight for the damper.
DrycogX
Type the offset distance along the x-axis for the dry center of gravity of the damper.
DrycogY
Type the offset distance along the y-axis for the dry center of gravity of the damper.
DryCogZ
Type the offset distance along the z-axis for the dry center of gravity of the damper.
WaterWeight
Type the water weight of the damper.
WaterCogX
Type the offset distance along the x-axis for the wet center of gravity of the damper.
WaterCogY
Type the offset distance along the y-axis for the wet center of gravity of the damper.
WaterCogZ
Type the offset distance along the z-axis for the wet center of gravity of the damper.
Width
Type the width of the damper.
DamperLength
Type the length for the damper.
Thickness
Type the thickness for the damper.
FlangeWidth
Type the width of the flange for the damper.
For the remaining properties, (i) indicates an integer corresponding to a nozzle number assigned to the cross section. This method avoids a lengthy listing for all possibilities, like Nozzle(1):CrossSection, Nozzle(2):CrossSection, and Nozzle(3):CrossSection for three possible nozzles. When you type the nozzle properties in the workbook, substitute a number for i to assign the nozzle to the appropriate property.
Nozzle(i):CrossSection
Type the related CrossSection object for the port as listed on the HvacSpec sheet.
Nozzle(i):EndPrep
Type the coded end preparation for Nozzle 1. The AllCodeLists.xls workbook contains mappings between numbers and components. For example, the number 11 in the Nozzle EndPrep column on the ManualDamper sheet corresponds to the flat-face flanged end, as specified in the AllCodeLists.xls workbook.
Nozzle(i):Thickness
Type the thickness of the nozzle port. The number of actual nozzles present on a cableway run can vary.
Nozzle(i):FlangeWidth
Type the flange width for the nozzle.
Nozzle(i):FlowDirection
Type the flow direction for the nozzle.
Nozzle(i):PortDepth
Type the depth of the port for the nozzle.
Nozzle(i):CptOffset
Type the offset value for the component.